Skip to main content

Style Options

Layout Style

Colors schema

Direction

Email :mail@muscatchemical.com Support : 00968 99489269
Whats APP:: Oman: +968 93960629
Oman:+968 99489269 UAE:+971569159739

BRINE CORROSION INHIBITOR RX

BRINE CORROSION INHIBITOR RX
SKU
RXSOL-40-4049-025
Supply Location::
Locations

BRINE CORROSION INHIBITOR RX manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of BRINE CORROSION INHIBITOR RX at a competitive price from us. We have ready stock of BRINE CORROSION INHIBITOR RX in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


MUSCAT CHEMICAL TAG::

Brine Corrosion Inhibitor RX  is a borate-organic corrosion inhibitor especially designed for use in chloride brine closed re-circulating cooling systems. Brine Corrosion Inhibitor RXSOL  provides effective corrosion protection for steel and most other metals in both low and high temperature systems and is formulated to perform without additional supplements. It can be used in chromate containing systems without causing precipitation.

Note

Features

  • Formulated for brine cooling systems
  • Liquid - easy to handle.
  • Multi metal corrosion protection.

Benefits

  • Can be used to replace chromate technology

Physical Properties :

- Odour: Odourless
- Appearance: colourless to yellow, miscible with water
- pH 11,5 - 14
- Boiling point 100 °C at 760 mm /Hg
- Density 1,155 - 1,190 g/cm3 at 20 deg C

Corrosion Inhibitor chloride brine closed re-circulating cooling systems.

The recommended dosage for Brine Corrosion Inhibitor RX is 17.5 litres per tonne of brine in the system. Brine Corrosion Inhibitor Rx may be added directly to the system either neat or in a water dilution. Dilutions should be made with evaporated water. If a chemical dosing pump is used then pump and lines should be mild steel, stainless steel, Teflon, polyethylene, PVC, polypropylene or rubber.

Conversion from chromate Brine corrosion inhibitor RX is compatible with chromate. Systems with chromate need not be flushed before adding the product. Let chromate deplete naturally and maintain boron level at a minimum of 70ppm. Brine Corrosion Inhibitor Rx should be fed slowly. Start feeding 5 to 10% of the total dosage at a time and watch for foaming. Gradually increase the feed rate. Brine Corrosion Inhibitor Rx does not induce foaming at normal dose rates, but if it is fed too much too soon, foaming may occur. Feed lines and pumps should be mild steel, stainless steel, Teflon, polyethylene, PVC polypropylene or rubber.

Testing and Control Control Brine Corrosion Inhibitor RX as Boron at 70 - 100 ppm Note: Because the specific gravity of the brine varies with concentration, the resulting level of boron should be calculated.

Copyright © 2021 Powered By MUSCAT AND BARKA BUSINESS TRADING - All Rights Reserved