Skip to main content

Style Options

Layout Style

Colors schema

Direction

Email :MUSCATCHEMICAL.COM @ gmail.com Support : 00968 99489269
Whats APP:: Oman: +968 93960629
Oman:+968 99489269 UAE:+971569159739

Acetylene Gas Cylinder

Acetylene Gas Cylinder
SKU
RXSOL-16-6154-040
Supply Location::
Locations

Acetylene Gas Cylinder manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Acetylene Gas Cylinder at a competitive price from us. We have ready stock of Acetylene Gas Cylinder in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


MUSCAT CHEMICAL TAG::
Category

Acetylene Gas marine bottle supplier on ship. In combination with oxygen, acetylene filling is used for gas cutting and welding. When blended with oxygen for welding, the fire temperature will achieve 3100º C 

 

Physical state at 20 °C :

Dissolved gas.

Colour   

Colourless gas.

Odour   

Garlic like. Poor warning properties at low concentrations.

Molecular weight

26

Melting point [°C] :

-80.8

Boiling point [°C] :

-84 (s)

Critical temperature [° C]:  

35

Vapour pressure [20°C] :

44 bar

Relative density, gas (air=1) :

0.9

Relative density, liquid (water=1) :

Not applicable

Solubility in water [mg/l] :

1185

Flammability range [vol% in air] :

2.34 to 83

Auto-ignition temperature [°C] :

325

 

Features

  • Colourless and slightly lighter than air
  • It is non-toxic, but has an anesthetic effect if inhaled
  • Acetylene is highly flammable
  • When mixed with oxygen for welding, the flame temperature will reach 3100º C

Benefits

  • For your safety, the product is delivered in a RXSOL cylinder complete with barcode and unique cylinder serial number.
  • We trace and track all cylinders using the UniTrak system to give you peace of mind.

Acetylene mixed with air is explosive within 2.2% to 85% by volume. Avoid releasing acetylene into the air and ensure good ventilation where acetylene cylinders are stored or used.

When acetylene cylinders are transported horizontally and placed vertically again after transport, a period of at least 24 hours before using the cylinders for gas extraction must be obeyed. This to ensure that the acetone inside the cylinder redistributes in a correct way. When cylinders are used too quickly after placing them vertical again the following can happen:

* When opening the top valve, large amounts of acetone can come out. The customer might interpret this as water/oil because acetone feels slippery on the skin. Opening the top valve without a fitted regulator should not be standard practice as this can create a fire hazard.

* When a regulator is fitted with twin hose and torch, the lighted flame will be very unstable due to the presence of acetone droplets in the gas. This is often referred to as “spitting”.

Solution is to let the cylinder rest for at least 24 hours (depending on temperature; colder environment might require longer time).

Tare "A" weight of acetylene cylinders includes cylinder shell, neckring, valve, porous mass and acetone. For acetylene the following is valid:
1 nm3 = 1.095 kg
1 kg = 0.91 nm3
1 bar = 14.5 psi
1 nm3 = 35.3 ft3
1 kg = 2.2 lbs

We are supplying welding and cutting items and gases particularly intended to meet the most noteworthy gauges of the overall marine industry and to perform under the most thorough shipboard conditions. 
Security is dependably a prime thought. From the spout blending outline of our slicing connection to the prescribed flashback arrestors and reverse discharge valves, no welder ought to be without. All items are intended to perform securely and dependably under the hardest states of shipboard utilize and bolstered with parts and administration through Dubichem Marine International in every significant port all through the world. 
 
Acetylene 
Dubichem Marine International acknowledges no duty regarding non-standard cylinders being arrived without earlier assent in composing. Dubichem Marine International will give typical barrel support including intermittent hydrostatic assessment and recertification and substitution of worn best valves at no cost to the ship proprietor. The repair of any harms caused by abuse or despicable taking care of by the client or missing valve security tops will be charged to the record of the ship proprietor. Drew Marine won't acknowledge for credit cylinders which have been subjected to bend consume, fire, fire or effect bringing about imprints or gouges. 
Acetylene A-40 General Description 
The Acetylene and Oxygen Distribution System gives the gas supply to the cutting/brazing applications locally available vessels. 
The Acetylene and Oxygen cylinders with chamber valves, T-valves, shutting valves and focal controllers might be arranged in isolated store on or over the upper constant deck with the cylinders put in an erect position and the controllers secured with wellbeing valves ventilated to outdoors. The outlet station is typically set in the motor room or in the workshop. On extraordinary reason ships, it might be put on open deck. 
Highlights 
Colourless and somewhat lighter than air 
It is non-poisonous yet has a soporific impact if breathed in 
Acetylene is very combustible 
When blended with oxygen for welding, the fire temperature will achieve 3100º C 
 
 
Safeguard and Information for clients/Owners 
Staying away from impacts which could harm either the shell and additionally permeable material; 
Shutting valves on purge cylinders; 
Keeping up the leftover weight inside the barrel; 
Denying transfilling of cylinders; 
Staying away from drenching in water 
 Encouraging not to conceal harm to cylinders that could, for instance, have been submerged or harmed, e.g. by repainting, and; 
 Putting away purge cylinders in committed territories with the valves shut. 
 
Technical 
Acetylene blended with air is unstable inside 2.2% to 85% by volume. Abstain from discharging acetylene into the air and guarantee great ventilation where acetylene cylinders are put away or utilized. 
At the point when acetylene cylinders are transported evenly and set vertically again after transport, a time of no less than 24 hours before utilizing the cylinders for gas extraction must be complied. 
This to guarantee that the CH3)2CO inside the chamber redistributes effectively. At the point when cylinders are utilized too rapidly subsequent to setting them vertical again the accompanying can happen: 
When opening the best valve, a lot of CH3)2CO can turn out. The client may decipher this as water/oil since CH3)2CO feels elusive on the skin. Opening the best valve without a fitted controller ought not be standard practice as this can make a fire peril. 
At the point when a controller is fitted with twin hose and light, the lit fire will be exceptionally unsteady because of the nearness of CH3)2CO beads in the gas. This is regularly alluded to as "spitting". 
The arrangement is to give the chamber a chance to rest for no less than 24 hours (contingent upon temperature; colder condition may require longer time). 
Tare "A" weight of acetylene cylinders incorporates barrel shell, neckring, valve, permeable mass and CH3)2CO. For acetylene the accompanying is legitimate: 
1 nm3 = 1.095 kg 
1 kg = 0.91 nm3 
1 bar = 14.5 psi 
1 nm3 = 35.3 ft3 
1 kg = 2.2 lbs

Copyright © 2021 Powered By MUSCAT AND BARKA BUSINESS TRADING - All Rights Reserved