Skip to main content

Style Options

Layout Style

Colors schema

Direction

Email :MUSCATCHEMICAL.COM @ gmail.com Support : 00968 99489269
Whats APP:: Oman: +968 93960629
Oman:+968 99489269 UAE:+971569159739

Copper Sulfate for Passivation Test

Copper Sulfate for Passivation Test
SKU
RXSOL-38-6116-500
Supply Location::
Locations

Copper Sulfate for Passivation Test manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Copper Sulfate for Passivation Test at a competitive price from us. We have ready stock of Copper Sulfate for Passivation Test in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


MUSCAT CHEMICAL TAG::
Category

The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials.

Question - What solution strength is needed to copper sulfate solution can be used to determine if a metal is stainless steel or just steel ? 
Answer    - Copper sulfate (CuSO4*5H2O) + H2SO4 (anywhere from 1% to 50% is specified in various test methods).

Detect the presence of metallic iron and iron oxide. Chromium and nickel will not be replaced with the Copper sulfate test solution, forming the distinctive copper color on the surface in this 6 minute test.

Remarks

Tag Identification

#Passivation_Test
#CopperSulfate_PassivationTest
#copperSULFATE_muscatDUBAI

Note


How does copper sulfate test for passivation work?

ANSWER : Chromium and nickel will not be replaced with the Copper sulfate test solution (which also contains sulfuric acid), only the Fe or other less noble metals. If there is free iron on the surface it will be replaced by the copper, forming the distinctive copper color on the surface in this 6 minute test. Of course, this test should only be used on austenitic stainless steel. Some people use it on other grades, but you can get false failures.

 

 

Click here for PASSIVATING LIQUID technical information , to know Other testing methods for PASSIVATION , Passivation Method


Spray the surface with a solution of copper sulfate in water. If free iron is present, a copper film will form. In this test, the chemical reaction is:

 Fe + CuSO4 = FeSO4 + Cu
The copper film is immediately visible.

 

Copper sulphate test: a galvanic type test in which the more noble copper plays upon less noble iron particles but not on SS.  Patches of copper sulphate shows a poorly passivated surface. Passivated parts are immersed in a Copper Sulfate solution for five minutes, rinsed and visually examined. Any copper (pink) color indicates the presence of free iron and the test is considered unacceptable.

Ferroxyl test: causes coloured iron compounds to appear as specks.



Copyright © 2021 Powered By MUSCAT AND BARKA BUSINESS TRADING - All Rights Reserved